Produkt: IB – Tron 3100FAN-BL-230V - Electronic controller to operate ventilation units, with backlight, with 3 gears, with power supply 12V

IB – Tron 3100FAN-BL-230V - Electronic controller to operate ventilation units, with backlight, with 3 gears, with power supply 12V DC

252,00 zł brutto 204,88 zł netto
  • Description
  • Pictures
  • Links
  • Features

IB-TRON 3100FAN

Basic information:

IB - Tron 3100FAN controller is independent microprocessor controller with large LCD display, dedicated to operate ventilation units. The controller allows to control 3-speed ventilation units, for which a switching signal of gears is short-circuit of suitable lines to mass or give voltage +12V on these lines.

IB - Tron 3100FAN controller allows to regulate air exchange in the building based on programmed timetable or in the manual mode.

IB - Tron 3100FAN controllers allow to save energy costs by appropriate adjustment of ventilation efficiency, according to needs. Controllers contribute to protect environment and financial savings. Controllers can be commonly used in: hotels, offices, supermarkets, factories, hospitals, houses and other buildings.

Features:

  • Large, backlit, LCD display which shows current speed of the fan, temperature, settings, a day of the week and other informations.
  • 3 speed of the fan (to choose).
  • Input to connecting a signal of clogged filter of ventilation unit. At the moment of short-circuit this input to the mass or give voltage +12V (choice of using by jumpers), on the display appears information about clogged filter and you will hear a beep.
  • Esthetic and modern design
  • Blue backlight (backlight is activated by pressing any button and deactivated after a certain period of inactivity)
  • Easy, intuitive operating and programming.
  • Power supply: AC or DC with possibility to power supply directly from the ventilation unit.
  • Comprehensive programming process in a weekly cycle with an accuracy of 1 minute and with possibility of programming four time periods each day.
  • Manual or automatic work mode.
  • Displayed temperature with resolution 0,1 oC
  • Support of additional digital input (to choice three work modes ).

Technical data:

  • Energy consumption: 2 W
  • Number of gears: 3
  • Storage temperature: -5 ÷ 50 ºC
  • Displayed temperature: -20 ÷ 140 ºC (every 0,1ºC )
  • Accuracy: 1 ºC
  • Power supply:
    • 12V - 24V DC
    • 12V - 18V AC
  • Active signal: short-circuit to mass or +12V
  • Signal of clogged filter: short-circuit to mass or +12V
  • Casing: ABS
  • Display: LCD (3,2``)
  • Control: Electronic
  • Protection rating: IP30
  • Memory of settings: 36 months
  • Dimensions: (height x width x depth):
    • Control Panel: 86 x 86 x 15 mm
    • Relay module: 62 x 45 x 27mm

General Considerations:

  • During installation of controller, the supply of electricity should be turned off. It’s recommended to entrust the installation a specialized institution.
  • The controller should be powered by constant voltage 12V-24V, however, it can be powered by alternating voltage 12-18V (effective value).
  • The controller is adapted to work with devices, for which active signal (speed control, sensor of filter) is short-circuit of suitable lines to mass or give voltage +12V (independent choice of a signal of control speed and clogged filter).

Scope of delivery:

  • 1x Controller (the main panel)
  • 1x Relay module
  • 1x Operating manual

Operating principle:

At work in automatic mode, controller at the beginning of each time period turns on programmed gear of central for this period. You can programme four time periods during the day and each of them assign one of three available speeds value.

In manual mode, user sets gear of central by himself. The central works on this gear all the time, until it is set another gear or controller is turned off.

Some of centrals allow to turn off the fan through an additional controller - for these centrals, in the IB-Tron 3100FAN controller is available the fourth state of working- turning off the fan.

The output of controller is enabled when it is shorted to mass or when voltage +12V is given on this output (depending on J3 jumper settings). When the controller is turned off all outputs which controll gears are inactive.

Structure:

IB-Tron 3100FAN controller consists of two parts: main panel with LCD display, keyboard and relay module, with RJ-12 connector to connect ventilation unit and digital input to connect additional buttons/panels.

Control Panel is adapted to surface-mounting or to mounting on a standard wiring box (spacing of holes- about 60mm, box- about 75x75mm). Relay module is predicted to be placed inside this box.

Both of modules are connected with each other by seven wire cable with a length of several centimeters.

Control Panel of Controller:

IB-TRON 3100FAN

LCD Display:

IB-TRON 3100FAN

Relay module:

IB-TRON 3100FAN

Identification of contacts in the RJ-12 socket:

„SI” - nput of clogged filter signal. Short-circuit this input to mass or give voltage +12V (choice of using jumpers) causes turning on an alarm.

„HI” - output of gear 3. This output is enabled, when controller wants to turn on gear 3 of ventilation unit.

„MED” - output of gear 2. This output is enabled, when controller wants to turn on gear 2 of ventilation unit.

„LO” - output of gear 1. This output is enabled, when controller wants to turn on gear 1 of ventilation unit or turn off the ventilation unit (depending on your type of central).

„COM” - mass of power supply (minus).

„+” - plus of power supply.

The controller can be alternatively powered by AC voltage. To do this, you have to give alternating voltage with a range from 12V to 18V between contacts: „+” and „COM”.

Digital Input:

The controller is equipped with additional digital inputs J2. Active signal for this input is short-circuit of its both contacts. To this input is typical connected monostable button (so-called ‚a bell button’), short-circuited while it’s pressing and returning to the gaping position after releasing the button (for example: used for doorbell). Altirnatively, one of the modes of support the input J2 predicts a connection of bistable switch (conventional, ‚switch on/ switch off’, e.g. to lighting).

Depending on the selected function (description later in this manual), the controller respectively changes a fan gear after the short-circuit digital input (pressing a button).

Signal of switching gear:

Changing jumper position (J3 jumper) we can choose, whether signal of turning on the fan gear has to be short-circuit corresponding output to the mass or give voltage +12V. J3 jumper is available without removing plate from casing.

Active signal will be short-circuit to mass, if jumper is set in GND position:

IB-TRON 3100FAN

Active signal will be voltage +12, if jumper is set in Vcc position:

IB-TRON 3100FAN

Signal of Clogged Filter:

IB-TRON 3100FAN

Controller allows to choice, whether signal of clogged filter is short-circuit input ‚SI’ to mass or give voltage +12V on this input. Changing position of jumpers J4A and J4B, a type of signal is changing.

Access to the jumpers is possible when the relay plate is ejected from plastic casing, towards arrow marked in the picture.

Active signal will be short-circuit input ‚SI’ to mass, if both of jumpers are set in 2-3 position (to short pins 2 and 3):

IB-TRON 3100FAN

Active signal will be voltage +12V on the input ‚SI’, if both of jumpers are set in the 1-2 position (to short pins 1 and 2):

IB-TRON 3100FAN

Setting jumpers J4A and J4B in different positions isn’t dangerous for system, but it causes its incorrect work.

Dimensions:

Main panel

IB-TRON 3100FAN

Relay module

IB-TRON 3100FAN

Connection:

Depending on your type of ventilation unit, outputs for connecting external controller may vary among themselves. Using manual, you have to connect suitable inputs of ventilation unit with the corresponding outputs of IB-Tron 3100 FAN controller.

Some of available recuperators in trade has RJ-12 socket to connecting external controller - identical socket as in the IB-Tron 3100 FAN controller. Some models can be connected directly to the controller, by ordinary network cable (wire ‚twisted pair’), made in a simple way i.e. with the same sequence of lines in plugs on both sides of twisted pair.

Before you buy this controller, make sure that your ventilation unit will cooperate with IB-Tron 3100FAN controller. To do this, please contact with technical department of Insbud company.

Below is presented exemplary connection of controller IB-Tron 3100FAN:

IB-TRON 3100FAN

Comments Related to Mounting:

Main panel with relay module is usually mounted in generally available room, e.g. in the sitting room or living room. Controller is connected with ventilation unit by multicore cable (wire ‚twisted pair’).

Controller can be powered directly from recuperator, if the recuperator has output to power these type of devices.

Length of twisted pair can be to several meters, depending on the level of electromagnetic interferences in the building.

Besides, to the relay module we can parallel connect from one to several buttons/switches, which are used to remote change the fan speed.

These buttons are typically mounted in the rooms, which from time to time require temporary increase of ventilation intensity e.g. in the toilet or in the kitchen.

Additional buttons you have to connect by two wire cable. Ideally, if it was twisted pair cables but it isn’t an absolute requirement. We can use a telephone cable or two wire cable type ‚cord’.

Installation of additional buttons is optional. If buttons are not mounted, J2 input has to be unconnected.

Main panel is adapted to mounting on a standard wiring box with width about 75mm and spacing of holes about 60mm. Relay module is predicted to be placed inside this box. Both of modules are connected with each other by seven wire cable with a length of several centimeters.

System Expansion:

System can be expanded with additional buttons in the simplest way, according to description. Using these buttons we can change the fan speed, but we can’t check on which gear the ventilation unit currently works or control state of filter.

Therefore, instead of usual buttons the user can install an additional panel IB-Tron 100AP with LEDs, which inform about current fan speed and state of filter. The panel has also monostable button fulfilling exactly the same function as buttons connected to the digital input J2, which is used to change speed.

Additional panel has an eight-pin socket RJ-45 and therefore it has to be connected with system by special splitter IB-SPL 01.

Additional panel IB-Tron 100AP.

IB-TRON 3100FAN

IB-TRON 3100FAN

Splitter IB-SPL 01

IB-TRON 3100FAN

For one divider you can connect two additional panels.

Additional panels are connected with divider by twisted pair, made in a simple way i.e. according to the same standard on both sides.

Apart from panels with LEDs to the system you can simultaneously connect usual monostable buttons, which are used to change the fan speed without the possibility of reading speed.

Turning on controller:

When the controller is turned off, on display is shown only current temperature. No output, which controls gears of ventilation unit is not active. When the controller is turned off, the function of detection clogged filter is still active.

Configurational menu:

In configurational menu are set parameters of controller work.

SController is in configurational mode. Displayed are: inscription ‚Menu’, setting number (from 01 to 11), code shortcut of setting (e.g. ‚CFG’), value and unit of setting.

Controller comes out of the configurational menu after a set time of inactivity or after pressing one of the buttons: ‚P’ or ‚OK’. Pressing button ‚OK’ or after time of inactivity causes save changes and exit the configurational menu. Pressing button ‚P’ causes cancel changes and exit the configurational menu.

Outputs configuration

For different ventilation units, which are available on market individual gears can be switched according to different standards. For example, for a large part of ventilation units absence of any signal from controller means switching on ventilation unit on the first gear. For another type, to switch on first gear you have to give signal on suitable input. Besides, some of ventilation units allow to turn off the fan through the included controller but others not allow this.

IB-Tron 3100FAN can control different types of ventilation units.User has ability to choose suitable signal’s standard for his ventilation unit. CFG parameter in configurational menu is used to this.

4 types of ventilation units were defined, for which outputs: LO, MED and HI are switched for each gears as in table:

CFG OFF Gear 1. Gear 2. Gear 3.
1 n.d. LO MED HI
2 n.d. X MED HI
3 LO X MED HI
4 X LO MED HI

 

n.d. - turning off the fan is not available;

x - all outputs (LO, MED, HI) are turned off;

For recuperators, which allow turning off the fan from the level of additional controller, CFG value should be 3 or 4. For recuperators without possibility of turning off the fan from the level of additional controller, CFG value should be 1 or 2.

Support of digital input:

User has ability to choose one of three modes of additional digital input support (J2). Mode 1 and 2 allows using the monostable button and mode 3 - bistable switch.

1. Ventilation After a short pressing the additional button connected to the input J2, follows temporary change of fan speed (instantaneous ventilation). User sets gear, which has to be switched and time of switching gear. For example: If the button is located in the kitchen, the user has possibility to instantaneous fan setting on the highest gear by one pressing a button e.g. when something starts to scorch. After the end of ventilation time, the controller switches gear again, on which the ventilation unit was before pressing button.

      • To exit the ventilation mode before the set time of ventilation, press additional button for about 3 seconds.

2. Increasing speed Short pressing button of each time causes increase fan speed. If ventilation unit is on the highest gear, pressing button causes switching of first gear (for recuperators without possibility of turning off the fan) or turning off the fan (for recuperators with possibility of turning off the fan). Sequence repeats over and over.

      • If controller is in manual mode (MANUAL), pressing the additional button causes lasting change of speed.
      • If controller is in automatic mode (AUTO), pressing the additional button causes transition to semi-automatic mode (OVERRIDE) - change of speed to the end of time segment. To go back to the automatic mode, press additional button for about 3 seconds.

3. Force speed This mode allows you connect additional bistable switch to the input J2. Switch can be placed for example close to the range hood. After additional switch is turned on, previous set of fan gear is activated until additional switch is turned off. After that controller is back in normal mode, and gear is set back to previous.

Temporary Speed:

When the ventilation function (INMOD parameter = 1) or force speed function (INMOD parameter = 3) has been assigned to the additional digital input J2, user should define, what fan speed will be run after pressing additional button (in ventilation function) or switching on (force speed function).

Parameters B_SPD are shown only when function of digital input is ventilation or force speed (when INMOD = 1 or 3).

Time of Ventilation:

When the ventilation function (INMOD parameter = 1) has been assigned to the additional digital input J2, user should define, how long after pressing additional button has to be ventilation.

Calibration

If temperature indicated on the controller is different than real temperature of the room, you have to calibrate sensor.

Time of Inactivity:

Time of inactivity this is a time, after which the controller comes out of parameters settings mode to default mode, counted from the last press of a button. Higher value gives the user more time to make settings.

Time of Backlight:

This is a time, after which is fading of LCD backlight, counted from the last press of a button.

Turning off Backlight:

IB-Tron 3100FAN controller is programmed to automatically turn off the backlight after time of backlight. Backlight is default turned off. However, you can set the controller so that don’t completely turn off backlight, but only reduce the intensity of backlight.

Temperature Units:

User has ability to choose if the temperature must be in (ºC) or (ºF).

Time Format:

User has ability to choose if the time must be displayed in 12-hour format or 24-hour.

Software version:

InsBud company supports policy of development. Thats why rights to making changes and improvements in products and manuals without prior notice reserved!

Our company is open to all suggestions to improve our controllers.

If you have an idea for new function or you need unusual solution of problem pleas contact us.

This manual concerns 03 verision.

Keyboard lock:

To protect controller from unwanted change settings, you can lock controller keyboard.

When keyboard lock is activated, on display is visible a padlock symbol and keyboard doesn’t respond to pressing keys.

Work Timetable - AUTO mode:

In the automatic mode you can set work timetable. It means automatic setting of programmed unit speed at concrete hour.

With timetable you can set lower intensity of ventilation in periods when e.g. building is not used or in nocturnal periods, and higher intensity when building is used.

You can program four time segments each day of the week, which were symbolically presented on display:

IB-TRON 3100FAN

  • After programming all four time segments the controller returns to standard displaying mode.
  • The fourth time segment lasts until the beginning of the first time segment the next day (e.g. from 9:00 p.m. on Monday to 7:00 a.m. on Tuesday).

Manual Mode:

In manual mode the controller constantly keeps desired speed of ventilation (without work timetable).

IB-TRON 3100FAN If controller works in manual mode, on display is visible hand symbol and time segment symbol is not visible.

  • Controller is in the manual mode until user doesn’t change it to automatic mode.

Additionally, if the external button (or buttons) is connected to the digital input J2 and INMOD parameter is set on value 2, pressing external button of each time causes increase fan speed.

If ventilation unit is on the highest gear, pressing external button causes switching of first gear (for recuperators without possibility of turning off the fan) or turning off the fan (for recuperators with possibility of turning off the fan). Sequence repeats over and over.

Individual gears correspond graphical representation of a bar chart at the bottom on the display:

  • ventilation unit is turned off - no bars
  • first gear - two bars;
  • second gear - four bars;
  • third gear - six bars;

Besides, fan symbol at the bottom on the display is animated faster or slower.

Semi-automatic Mode

In semi-automatic mode is manual speed correction in current time segment. It means setting other speed for current time segment than in the timetable. After the end of the current time segment, controller returns to the automatic mode and works with the timetable.

  • You can move to semi-automatic mode only from automatic mode.

Additionally, if the external button (or buttons) is connected to the digital input J2 and INMOD parameter is set on value 2, and controller works in automatic mode, pressing external button of each time causes increase fan speed and entrance to semi-automatic mode.

You can come out from semi-automatic mode by pressing button ‚OK’ or pressing and hold for about 3 seconds the external button.

Errors:

When ventilation unit gives a signal of clogged filter, on display is inscription ‚FILTER’ and you will hear a beep ( also when the controller is turned off). After cleaning or changing filter, signaling should disappear.

Supplement:

Placement of configurational jumpers: J3, J4A and J4B may be differ than placement shown in previous chapters of this manual, depending on the current batch production of the controller.

Both versions are identical as regards electrical diagram and functionality.

IB-TRON 3100FAN

Configuration rules are constant:

  • Jumper J3 in the GND position - switching signal of gear is short-circuit lines to mass.
  • Jumper J3 in the Vcc position - switching signal of gear is voltage +12V.
  • Jumpers J4A and J4B in the position 1-2 - signal of clogged filter is voltage +12V on the input „SI”.
  • Jumpers J4A and J4B in the position 2-3 - signal of clogged filter is short-circuit input „SI” to mass („COM”).

v4.1

  • Parameters
    • Number of supported temperature sensors 1
    • Number of relays (total) 3
    • Ethernet communication Nie
    • RS-485 communication Nie
    • Remote control Nie
    • Backlight Tak
    • Controlling Elektroniczne
    • Power supply 12V DC